Available phases are:
BioPro HIC columns are characterised by:
- High resolutions
- Short run times
- High throughput
- Excellent lot-to-lot reproducibility
- Long term stability
- No carryover effects
Applications
Application | Column | Compound name | |
Antibody drugs by HIC using Isopropanol | BioPro HIC BF | Adalimumab (Humira®) Brentuximab Pembrolizumab (Keytruda®) Reslizumab (Cinqaero®) | |
Antibody drugs by HIC using ammonium sulphate | BioPro HIC BF | Bevacizumab (Avastin®) Rituximab (MabThera®) NIST mAb Trastuzumab (Herceptin®) Adalimumab (Humira®) | |
Antibody drugs by HIC using sodium chloride | BioPro HIC BF | Bevacizumab (Avastin®) Rituximab (MabThera®) NIST mAb Trastuzumab (Herceptin®) Adalimumab (Humira®) | |
Drug-to-Antibody Ratio (DAR) analysis of ADC | BioPro HIC BF | Cysteine-conjugated ADC mimic | |
High throughput DAR determination of brentuximab vedotin (Adcetris®) by reducing the analysis time | BioPro HIC HT | Brentuximab vedotin (Adcetris®) | |
Online native HIC-MS analysis of a monoclonal antibody mixture | BioPro HIC BF | 7 different Monoclonal Antibodies | |
Online native HIC-MS analysis of a monoclonal antibody molecular variants | BioPro HIC BF | 2 different Monoclonal Antibodies | |
Online native HIC-MS analysis of cys-linked ADCs | BioPro HIC BF | Cysteine conjugated ADC mimic deglycosylated | |
Protein Analysis by HIC | BioPro HIC BF | Myoglobin Ribonuclease A Lysozyme α-Chymotrypsinogen A |
Specifications
BioPro HIC HT
|
BioPro HIC BF
|
|
Base Material | hydrophilic polymer (polymethacrylate) | |
Particle Size [µm] | 2.3 | 4 |
Pore Size | non-porous | |
pH Range | 2.0 - 12.0 | |
Pressure Limit | 40 MPa / 5,800 psi | 20 MPa / 2,900 psi |
Temperature Range | 10 - 60°C |
Phase Details
BioPro HIC HT
Base Material | hydrophilic polymer (polymethacrylate) |
Particle Size | 2.3 µm |
Pore Size | non-porous |
Modification | butyl |
pH Range | 2.0 - 12.0 |
Pressure Limit | 40 MPa / 5,800 psi |
Temperature Range | 10 - 60°C |
BioPro HIC BF
Base Material | hydrophilic polymer (polymethacrylate) |
Particle Size | 4 µm |
Pore Size | non-porous |
Modification | butyl |
pH Range | 2.0 - 12.0 |
Pressure Limit | 20 MPa / 2,900 psi |
Temperature Range | 10 - 60°C |
Technical Library
Title | Document Type | Language | Download |
Analysis of oxidised monoclonal antibodies using BioPro HIC BF | Application Note | EN | |
HIC Analysis of Different Monoclonal Antibodies using Isopropanol as Modifier | Application Note | EN | |
HPLC Analysis of Drug-to-Antibody Ratio with BioPro HIC BF by YMC | Application Note | EN | |
High throughput DAR determination of brentuximab vedotin using YMC's BioPro HIC HT | Application Note | EN | |
Online native HIC-MS analysis of MAbs and their molecular variants using BioPro HIC BF | Application Note | EN | |
Online native HIC-MS analysis of cys-linked ADCs using BioPro HIC BF | Application Note | EN | |
Separation of plasmid isoforms using BioPro HIC BF | Application Note | EN | |
The right HIC column for each separation- BioPro HIC HT and BioPro HIC BF | Application Note | EN | |
YMC Application Collection - Antibodies & ADCs | Application Note | EN | |
BioPro HIC HT and BioPro HIC BF Care and Use | Care and Use Instructions | EN | |
YMC Biochromatography Columns | Catalogue | EN | |
YMC Biochromatography Columns (HQ) | Catalogue | EN | |
YMC Biochromatography Columns - HIC Columns Chapter | Catalogue | EN | |
Efficient HIC plasmid isoform analysis | Expert Tip | EN | |
Analytical Stationary Phases for BioLC from YMC | Overview | EN | |
YMC Alternatives to Existing BioLC Columns | Overview | EN | |
The Principles of BioLC & YMC BioLC Phase Overview | Poster | EN | |
About the resolving power of non-porous HIC columns for intact protein analysis | Technical Note | EN | |
Characterisation of mAbs and related products via HIC-MS | Technical Note | EN | |
Charakterisierung von monoklonalen Antikörpern und verwandten Produkten via HIC-MS | Technical Note | DE | |
Strategies to Improve Your HIC Analysis | Technical Note | EN | |
Welcher LC-Modus ist besser für verschiedene ADC-Typen geeignet? RP oder HIC? | Technical Note | DE | |
Which LC-mode is more suitable for different ADC-types? RP or HIC? | Technical Note | EN | |
Grundlagen der Chromatographie für die Analyse und Aufreinigung von Biologika | Whitepaper | DE |
Ordering Information
Please login to see the prices.
- 2-3 days
- 1-2 weeks
- 3-4 weeks
Product | Description | Price | Stock |
BHB00S04-1010WT | BioPro HIC BF, non-porous, semi-preparative HPLC column (10 mm ID), S-4 µm, 100 x 10 mm | - 14831 CHF 12097 € | |
BHB00S04-1046WT | BioPro HIC BF, non-porous, HPLC column (4.6 mm ID), S-4 µm, 100 x 4.6 mm | - 2137 CHF 1743 € | |
BHH00SQ3-1046PTH | BioPro HIC HT, non-porous, HPLC column (4.6 mm ID), S-2.3 µm, 100 x 4.6 mm | - 2367 CHF 1931 € | |
BHH00SQ3-H346PTH | BioPro HIC HT, non-porous, HPLC column (4.6 mm ID), S-2.3 µm, 33 x 4.6 mm | - 1828 CHF 1491 € | |
XRPRCP02 | Precolumn filter 2 µm for 1/16" OD + holder, PEEK (350 bar) | - 353 CHF 288 € | |
XRPRCP25 | Replacement precolumn filter 2 µm for 1/16" OD, PEEK (350 bar) | - 257 CHF 210 € | |
XRPRCS03 | Precolumn filter 0.5 µm for 1/16" OD + holder, stainless steel (600 bar) | - 353 CHF 288 € | |
XRPRCS35 | Replacement precolumn filter 0.5 µm for 1/16" OD, stainless steel (600 bar) | - 257 CHF 210 € |