Optimized solutions for biomolecule separations

Biochromatography Columns

YMC’s biochromatography columns (BioLC Columns) are specifically designed for the precise separation and purification of biomolecules such as proteins, peptides, nucleotides, and antibodies. Optimized for HPLC & UHPLC, these columns ensure high resolution, reproducibility, and minimal sample loss, even for sensitive biomolecules. Our BioLC column portfolio includes ion exchange (IEX) columns for charge-based separations, size exclusion (SEC) columns for molecular weight-based fractionation, and reversed-phase bioseparation (RP Bio) columns for hydrophobic interactions. Additionally, bioinert and hydrophobic interaction chromatography (HIC) columns offer tailored solutions for challenging bioanalytical applications. Explore YMC’s high-performance biochromatography solutions and find the optimal column for your specific separation needs.

Read more

Your next step
to first class products

Would you like to learn more about our products or
schedule a personal appointment? Please feel free to contact us!

Contact us

Expert Topics

Troubleshooting Support for HPLC

Having issues with your HPLC system? Our troubleshooting guide offers solutions for common problems, ensuring optimal performance in your analytical processes.

Read more

Expertise portal: More expert content for you

In our expertise area, we have compiled extensive knowledge and supporting digital services for you. Use our extensive knowledge database and the numerous calculators of our expertise portal.

Read more

Online presentations: Experience us live

In our online presentations, we pass on our expert knowledge to you and answer all your questions. Book an online presentation on a specific topic and meet us live.

Read more

Guide to Biochromatography Columns for HPLC & UHPLC

What Is Biochromatography?

Biochromatography is a specialized field of HPLC & UHPLC designed for the separation, purification, and analysis of biomolecules such as proteins, peptides, nucleotides, and antibodies. Unlike conventional chromatography, biochromatography columns are optimized to maintain sample integrity, high binding capacity, and reproducible separations. YMC offers a comprehensive range of BioLC Columns, covering multiple chromatographic techniques to suit different biomolecule characteristics.

Types of BioLC Columns and Their Applications

Ion Exchange (IEX) Columns: Used in IEX chromatography for charge-based separation of biomolecules. Ideal for protein purification, nucleic acid separations, and antibody analysis.

Size Exclusion (SEC) Columns: Fractionate molecules by molecular weight, widely applied for antibody aggregation studies and biopharmaceutical characterization.

RP Bioseparation Columns: Specialized RP Bio Columns for hydrophobic interactions, crucial for peptide and protein separations in biochromatography.

Hydrophobic Interaction (HIC) Columns: Separate antibodies, protein conjugates, and ADCs based on hydrophobicity, ensuring high recovery and resolution.

Bioinert Columns: Prevent metal interactions for sensitive biomolecules, including phosphopeptides, oligonucleotides, and phospholipids.

Advantages of YMC BioLC Columns


High resolution & peak symmetry:
Achieve optimal separation of complex biomolecules.

Scalability: Fully compatible with both analytical and preparative HPLC & UHPLC applications.

Wide range of pore sizes & selectivities: Tailored solutions for various molecular weights and hydrophobic properties.

Optimized for biopharmaceutical applications: Designed for antibody analysis, protein purification, and proteomics workflows.

 

Choosing the Right BioLC Column

Selecting the right BioLC column depends on the properties of the biomolecules being analyzed. Ion Exchange Chromatography (IEX) is ideal for separating charged molecules like proteins and nucleic acids using anionic or cationic exchange phases. Size Exclusion Chromatography (SEC) columns separate biomolecules based on molecular size, making them essential for antibody aggregate analysis and protein fractionation.

For hydrophobic biomolecules, Reversed Phase Bioseparation (RP Bio) Columns provide high-resolution separations, while Hydrophobic Interaction Chromatography (HIC) Columns offer a gentler approach for protein complexes and antibody-drug conjugates (ADCs). Bioinert-coated columns prevent metal interactions, ensuring high recovery of sensitive compounds like phosphopeptides and oligonucleotides.

With its broad selection, YMC provides optimized solutions for bioanalytical workflows in pharmaceutical research, biopharmaceutical development, and proteomics.

Find Your Ideal BioLC Column

YMC’s biochromatography columns ensure high efficiency, robust performance, and superior biomolecule recovery in HPLC & UHPLC applications. Whether you are working in pharmaceutical research, biopharmaceutical development, or proteomics, YMC provides tailored solutions for your bioanalytical workflows.

Need help selecting the right column? Contact YMC Europe for expert consultation.

Contact us for consultation
  • YMC Europe GmbH
  • Phone +49 2064 427-0
  • Schöttmannshof 19
  • Fax +49 2064 427-222
  • D-46539 Dinslaken